Why Choose Fire-Retardant Wood?
Fire-retardant wood makes it possible to combine wood’s natural and aesthetic qualities with the fire safety requirements of today’s construction projects. Through a documented and verified fire-retardant treatment, wood can be used in applications where untreated wood does not meet current fire safety requirements.
For the building owner, this means greater freedom in material selection, while the project’s fire performance can be verified through testing, classification, and associated documentation. This creates better conditions for meeting the project’s requirements without compromising on architecture, function, or sustainability.
Furthermore, when fire-retardant wood is certified and verified for its intended use environment—for example, through a documented use class where required—it provides a more reliable foundation for both the construction phase and long-term management.
Fire-retardant wood is not just about meeting a fire code requirement—it’s about creating the conditions for safe, sustainable, and long-term wood construction.
How do I know that the solution meets regulatory requirements?
To demonstrate that a solution meets the project’s requirements, it must be documented and verified in accordance with relevant standards, classifications, and applicable building codes. The documentation must also be relevant to the specific product, the structure, and the environment in which it will be used.
For wood facades, it is not always sufficient for an individual product to have a fire class. It is also important to ensure that the intended structure is covered by the documentation, tests, and any approvals that form the basis of the solution.
Reviewing the documentation as early as the design phase creates better conditions for an efficient construction project, reducing the risk of additional work, delays, and questions during technical consultations, inspections, and final approval.
A well-documented solution provides a more reliable foundation for design, the regulatory approval process, and long-term management.
Are two products with the same fire rating always equivalent?
No. Two products may achieve the same fire class, but still differ in terms of documentation, verified scope of use, durability, and the types of structures for which they have been tested and classified.
When selecting a fire protection solution, it is therefore important to evaluate the entire technical documentation—not just the declared fire resistance class. Factors such as the product’s Field of Application (FoA), verified use class where applicable, system testing, and third-party-monitored manufacturing can have a significant impact on how the solution is intended to be used and verified.
A well-documented solution provides a better basis for decision-making and greater peace of mind throughout the entire construction process—from design and construction to facility management.
What sets Woodsafe apart from other suppliers?
Since 1990, Woodsafe has specialized in the industrial fire-retardant treatment of wood and plywood. The company’s operations cover the entire chain—from research, product development, and testing to industrial production, quality assurance, and technical documentation.
Manufacturing takes place under continuous third-party-monitored production control and is supported by certified management systems in accordance with ISO 9001, ISO 14001, , and ISO 45001. Woodsafe was also the first manufacturer in Europe to obtain CE certification for fire-retardant-treated wood and is currently involved in more than 1,300 construction projects each year in Europe and on international markets.
For the developer, this means a supplier with extensive experience, documented technical expertise, and solutions used in everything from residential buildings and schools to complex public buildings, infrastructure projects, and international landmarks.
Woodsafe’s strength lies in the combination of extensive experience, verified documentation, quality-assured production, and a clear focus on long-term fire safety performance.
How does Woodsafe ensure long-term fire performance?
Long-term fire performance is a key aspect of the development and verification of Woodsafe’s fire protection solutions. Therefore, we continuously conduct research, testing, product development, and quality assurance to document how the performance of the fire protection system is affected over time.
Woodsafe’s products are tested and classified in accordance with relevant European standards. For products intended for exterior use, durability is verified, among other things, through testing in accordance with EN 16755, where fire performance is evaluated before and after standardized accelerated aging. For facade solutions, there are also documented system tests and full-scale fire tests that verify the fire performance of the entire structure.
At the same time, Woodsafe conducts extensive research and development on the natural aging of wood, exterior exposure, and long-term fire performance through ASSURED™, a research program that combines natural exposure and artificial aging with accredited fire testing in accordance with ISO/IEC 17025.
For the building owner, this provides a basis for decision-making grounded in documented verification, continuous research, and technical development—with a focus on how fire-retardant wood products perform, not only at the time of delivery but also throughout their intended service life.
Woodsafe’s ambition is not only to verify fire performance at the time of delivery—but also to build knowledge about how fire-retardant wood products perform throughout their entire intended service life.
What certifications and documentation does Woodsafe offer?
Woodsafe’s operations are based on verified quality, third-party-monitored production, and traceable documentation throughout the entire manufacturing process.
Depending on the project’s requirements, the documentation may include, among other things, CE marking, declarations of performance (DoP), classification reports, type approvals, Field of Application (FoA), documented service class according to EN 16755, full-scale facade tests according to SP FIRE 105, and other technical documentation relevant to the specific product and application.
The comprehensive documentation provides designers, contractors, inspection supervisors, and building owners with a clear basis for design, verification, and inspection. It contributes to a more efficient construction process and provides assurance that the selected solution is documented for its intended use.
Documentation is not just a requirement—it is the foundation for traceability, verification, and long-term fire safety and security.
In what types of projects are Woodsafe's solutions used?
Woodsafe’s fire-resistant wood products are used in a wide range of construction projects—from residential buildings, schools, and healthcare facilities to airports, cultural buildings, public spaces, infrastructure projects, and advanced wood structures with stringent fire safety requirements.
Reference projects include the , Mjøstårnet, Gardermoen Pier North, Ilulissat Icefjord Centre, Cederhusen, and a large number of other projects in Europe and on international markets. What they all have in common are high requirements for documented fire performance, quality, long-term functionality, and technical verification.
This broad project portfolio demonstrates that Woodsafe’s solutions are used in buildings where safety, documentation, and long-term reliability are critical.
Today, Woodsafe participates in over 1,300 construction projects each year—ranging from local construction projects to some of the world’s most high-profile wood buildings.
How do I monitor fire safety throughout the construction process?
Fire safety measures should be monitored throughout the entire construction process—from design and procurement to delivery, installation, self-inspections, and final approval.
This means ensuring that design requirements, technical documentation, and the materials delivered and installed are consistent with the selected solution. Any deviations should be identified and addressed before installation or continued production.
A traceable and well-documented process facilitates self-inspections, verification, and the final handover of the building. At the same time, it reduces the risk of deviations, additional work, and unnecessary delays during the course of the project.
Continuous monitoring throughout the entire construction process is essential to ensure that the finished building meets the project’s requirements and documented fire performance.
Why do so many builders choose Woodsafe?
For building owners, choosing a supplier involves more than just meeting a fire safety requirement. It’s about selecting a partner with proven experience, technical expertise, and the ability to contribute throughout the entire construction process—from design and procurement to the completed building and long-term management.
Since 1990, Woodsafe has specialized in industrial fire-retardant treatment of wood and plywood. The company combines over 35 years of experience with research, product development, quality-assured production, and international collaborations. The products are verified according to relevant standards and supported by comprehensive technical documentation and third-party monitored manufacturing.
Today, Woodsafe’s solutions are used in more than 1,300 construction projects each year, ranging from residential buildings and schools to complex public buildings, infrastructure projects, and international wood-frame structures with stringent requirements for documented fire performance.
For the building owner, this means a solid basis for decision-making, long-term peace of mind, and a partner with experience in translating technical requirements into verified solutions.
Woodsafe’s mission is not only to supply fire-protected wood—but also to contribute to safe, verified, and long-term sustainable wood buildings.
How do I ensure that the right requirements are included in the procurement process?
A clear set of requirements is one of the most important prerequisites for a successful construction project. The earlier the correct requirements are defined, the lower the risk of misunderstandings, additional work, and costly changes down the line.
In addition to the desired fire class, the procurement process should, where relevant, also include requirements for documented performance, the applicable Field of Application (FoA), a verified service class, third-party supervised production, as well as the documentation and system tests required for the specific design and usage environment.
A well-developed requirements specification creates better conditions for design, procurement, construction, and final verification—while reducing project risk and providing a clearer basis for decision-making for all parties.
Clear requirements from the outset are often the simplest path to a safer and more cost-effective construction project.